子午工程二期电离层数字测高仪样机测试与数据质量对比分析

Digisonde prototype testing and data quality comparison analysis for Phase II of Chinese Meridian Project

  • 摘要: 为确保国产设备的探测质量,子午工程二期建设的电离层数字测高仪采用与成熟型号DPS-4D对比的方式,在位于海南儋州的空间天气国家野外科学观测研究站开展了样机测试. 对参试设备及参试过程进行了介绍,对数据质量对比测试结果进行了详细分析. 样机测试包括现场技术指标测试和数据质量对比分析. 数据质量分析从频高图质量、电离层特征参量(foF2、hmF2、h'F2、自动度量和手动度量)、电离层漂移速度等多个方面进行综合对比,明确了样机的硬件和数据处理软件的技术状态. 技术指标测试结果表明,样机的两通道峰值发射功率不超过686 W;两发射天线驻波比不超过2.23;接收通道灵敏度达到−125 dBm,接收动态范围达到105 dB;接收带宽70 kHz,带外抑制超过100 dB. 数据质量对比结果表明,样机自动与手动度量的foF2平均偏差0.02 MHz,hmF2平均偏差28.39 km,h'F2平均偏差0.39 km;样机与DPS-4D手动度量的foF2平均偏差−0.13 MHz,hmF2平均偏差14.7 km,h'F2平均偏差−3.21 km. 分析结果表明,样机在硬件的基础探测能力方面与DPS-4D相当,频高图度量的算法还存在改进空间. 本次样机数据质量对比,不仅服务于子午工程二期电离层数字测高仪的技术定型,也为数字测高仪数据质量评估指标的确定提供了参考.

     

    Abstract: To ensure the detection quality of the domestic model ionospheric digisonde adopted by the Phase II of Chinese Meridian Project, prototype testing including technique testing and a data quality comparison was performed. The test was carried out in the National Space Weather Observation Station in Danzhou, Hainan. After the prototype digisonde testing process was introduced and completed, the data quality evaluation results were analyzed in detail. A thorough comparison demonstrated that the prototype reached the overall standard established by the mature-type DSP-4D in the aspects of quality of ionograms, accuracy of ionospheric parameters (h'F2, hmF2, foF2, auto-scaled or manual-scaled), and drift velocity. According to the testing results of technical indices, the peak power of the two transmitting channels is no more than 686 W, and the voltage standing wave ratio is no more than 2.23. The sensitivity of the receiving channel reached −125 dBm, and the dynamic range reached 105 dB. The baseband bandwidth of the digital receiver is 70 kHz, and the suppression of outband interference is no less than 101 dB. The results of the data quality evaluation showed that the average differences between the prototype digisonde parameters of Fof2, h'F2, and hmF2 obtained using auto-scaling and manual scaling are 0.02 MHz, 28.39 km, and 0.39 km, respectively. The average differences between the three parameters of the prototype digisonde and those of the DPS-4D obtained using auto-scaling are −0.0 MHz, −2.61 km, and −9.12 km, respectively. The average differences between the three parameters of the prototype digisonde and those of the DPS-4D obtained using manual scaling are −0.13 MHz, 14.7 km, and 3.21 km, respectively. The prototype testing clarified the status of the technique of the domestic instrument, greatly contributing to its design optimization and finalization. It also established a reference for digisonde data quality assessment.

     

/

返回文章
返回